Flytec 6010/6005 User Manual

Page 17

Advertising
background image

16

Operating Instructions Flytec 6005/6010




Option 3:

Unit

[Set speed units]

Use the Arrow Keys to set the units for the speed display.
The choices are kilometers per hour (

km/h

), knots or (

kts

), or

miles per hour (

mph

).

Short press





Option 4:

STALL

The Stall Alarm threshold can be set from 6 mph upward,
using the Arrow Keys. You can switch the Stall Alarm off by
setting it to 0 mph




Short press


Option 5:

Corr SPEED

[Airspeed correction]

Use the Arrow Keys to set an airspeed correction value to
compensate for sensor inaccuracy or errors created by the
sensor placement. The correction can be set to +/- 50% of
measured airspeed, in 1% increments.

The accuracy of the speed displayed is greatly influenced by
the mounting position of the speed sensor. Therefore, you
should take care to mount it in clear, unobstructed air – both
fore and aft of the sensor.

Short press





Option 6:

SPEED DISP

[Speed Display]

SPEED DISP

shows whether, and at what time interval, the

display will alternate between airspeed and temperature.

The Use the Arrow Keys to choose from the following can be
chosen:

- speed only

- change after 30 seconds

- change after 60 seconds

- change after 120 seconds

Short

press

to return to option 1


The temperature display will appear for four seconds. If no
speed sensor is plugged in, only temperature will be
displayed.

Advertising