Option-mode alt1 – Flytec 6010/6005 User Manual

Page 9

Advertising
background image

8

Operating Instructions Flytec 6005/6010


Option-Mode ALT1

From

ALT1

Set-Mode, press the Altitude Key for three

seconds to bring the instrument into Option-Mode. After
making each change, use a quick press on this key to
confirm and go to the next option, or wait three seconds to
keep your changes and return to Run-Mode.

Press 3 sec.




Option 1:

Unit

[set altitude units]

Use the Arrow Keys to set the units of altitude to feet or
meters

.


Short Press






Option 2:

Unit

QNH [set pressure units]

Use the Arrow Keys to set the pressure units for

ALT1

to

hPa

or

inHg.





Short Press





Option 3:

Corr

[correct air pressure]

Use the Arrow Keys to correct the pressure for

ALT1

. This

may become necessary after several years of use (see the
section on Care & Maintenance below). The maximum
correction possible is +/- 47.9 hPa.





A short press of the Altitude Key cycles you back to
Option 1.