CS725 Snow Water Equivalency Sensor

humidity of the soil specified in the parameter HCalib. When this is
done, the new values of n0Ke and n0Tl will be stored in the
parameter block, and the operation mode will be changed internally
by the CS725 to automatic (code = 0).

The automatic mode (code =0) is the normal mode of operation. The
CS725 will continuously cycle through 24-hour periods, calculating
the SWE for the previous 24 hours at 6 hours intervals.

16. [.s]


The [.s] command is used to display status and current measurement
information:

System status:
-Present time

: 05/11/2010 12:40:05

-Firmware Version

: 5c

-Software Version

: 15_L

-V bat(Volts)

: 12.64

-V HV (Volts)

: 380.02

-V HV-DAC (code)

: 20472

|-Data acquisition start time

: 05/11/2010 12:37:15

-Data acquisition stop time

: 06/02/2136 06:28:15

-Next Results Xmission time : 06/02/2136 06:28:15
-Elapsed time,current histo

: 00:02:39

-Mode

: MANUAL

-Automatic heating

: disabled

-TMax

: 24 0 0 0

-Min

: 24 0 0 0

17. [.0xps]


[.0xps] Parameters save to file function

The [.0xps] command is used to save the parameters list from the CS725
in a text file. It is useful when a new CS725 replaced an old CS725 at a
site. The CS725 will prompt:

Enable the screen capture to a file with the Hyper Terminal to begin the
transfer of parameters, type S (CR)

where CR is the enter key. Before typing S, the file will be named using
the Hyper Terminal function.

18. [.0xpr]


[.0xpr] Parameters recovery from file function

The [.0xpr] command is used to recover the parameters list from a text file
created with the [.0xps] command and send the list to the CS725. It is
useful when a new CS725 replaced an old CS725 at a site. The CS725
will prompt :

Allocating tempory buffer,,,,,,,,,
Launch the parameter file transfer with the Hyper Terminal