Campbell Scientific CS725 Snow Water Equivalency Sensor User Manual

Page 42

Advertising
background image

CS725 Snow Water Equivalency Sensor

Alias CS725_Date_Time(1) = CS725_Day
Alias CS725_Date_Time(2) = CS725_Month

Alias CS725_Date_Time(3) = CS725_Year
Alias CS725_Date_Time(4) = CS725_Hour
Alias CS725_Date_Time(5) = CS725_Min


Public CS725_StationID As String * 10
Public CS725_Values(17) As Float


Alias CS725_Values(1) = CS725_SerialNum
Alias CS725_Values(2) = CS725_K_Uncorrected

Alias CS725_Values(3) = CS725_K_Counts
Alias CS725_Values(4) = CS725_TL_Counts
Alias CS725_Values(5) = CS725_SWE_K

Alias CS725_Values(6) = CS725_K_TL_Ratio
Alias CS725_Values(7) = CS725_SWE_TL
Alias CS725_Values(8) = CS725_SM_K

Alias CS725_Values(9) = CS725_SM_TL
Alias CS725_Values(10) = CS725_SM_K_TL
Alias CS725_Values(11) = CS725_Precip_Index

Alias CS725_Values(12) = CS725_Crystal_TEMP_MIN
Alias CS725_Values(13) = CS725_Crystal_TEMP_MAX
Alias CS725_Values(14) = CS725_Hist_Blocks

Alias CS725_Values(15) = CS725_K_Disp
Alias CS725_Values(16) = CS725_Stats
Alias CS725_Values(17) = CS725_PWR_Volt


Public CS725SplitStr(20) As String * 16

Dim loopcount As Long

'Declare Constants

'Command to Read back last results in short data output form
'preceed .flla with an ESCAPE key CHR(27) and emd with an Enter CHR(13)
Const CS725_Command_get_output = CHR(27) + ".flla" + CHR(13)


'Define Data Tables
DataTable (Diagnostics,1,-1)

DataInterval (0,1440,Min,10)
Minimum (1,batt_volt,FP2,0,False)
Maximum (1,batt_volt,FP2,0,False)

Minimum (1,PTemp,FP2,0,False)
Maximum (1,PTemp,FP2,0,False)
EndTable


'Define Data Tables
DataTable (CS725_6Hour,1,-1)

DataInterval (30,360,Min,10)
Sample (1,CS725_TIME_String,String)
Sample (1,CS725_StationID,String)

Sample (1,CS725_SerialNum,IEEE4)
Sample (1,CS725_K_Counts,IEEE4)
Sample (1,CS725_TL_Counts,IEEE4)

Sample (1,CS725_SWE_K,IEEE4)
Sample (1,CS725_K_TL_Ratio,IEEE4)
Sample (1,CS725_SWE_TL,IEEE4)

Sample (1,CS725_Crystal_TEMP_MIN,IEEE4)
Sample (1,CS725_Crystal_TEMP_MAX,IEEE4)
Sample (1,CS725_Hist_Blocks,IEEE4)

Sample (1,CS725_K_Disp,IEEE4)
Sample (1,CS725_PWR_Volt,IEEE4)
EndTable

34