Name

The Name used to identify this datalogger in LoggerLink.

Data files collected from this datalogger will be stored in a

sub-directory with this name.

PakBus Settings

Address

The PakBus Address of the datalogger you will be

connecting to. The valid range is 1 through 4094.

However, PakBus addresses greater than 3999 are typically

reserved for PakBus routing devices and ports.

Neighbor

The PakBus address of the neighbor you will go through to

connect to your datalogger. A value of 0 means you will

connect directly to your datalogger.

Security Code

The Security Code is only required if security has been

enabled on your datalogger. In order for LoggerLink to

connect to a security-enabled datalogger, the security code

of at least level 3 is required. The level 3 security code

allows you to check the clock and collect data. The level 2

security code is required to set the clock or change public

variables. The level 1 security code unlocks the highest

level of security and allows you to change or retrieve the

program as well as change status table variables.