0 technical specifications – Campbell Scientific Morningstar SunSaver-10 10A 12V Regulator User Manual

Page 16

Advertising
background image

16

101E-R4-2/00

8.0 TECHNICAL SPECIFICATIONS

RELIABILITY

5-year failure rates at a 95% confidence level

• SunSaver-6 ........................................ < 0.1%

• SunSaver-10 ......................................

<

0.2%

PERFORMANCE / ELECTRICAL

• Accuracy:

Sealed............................................ +/–35 mV

Flooded ........................................ +/–60 mV

LVD ................................................ +/–100/160
mV

• Maximum array voltage .................... 25 V/44 V

• Minimum voltage to operate............ 6 V

• Ground .............................................. negative

• Parallel capability .............................. yes

• Self-consumption: ............................ 8 to 10 mA

• Voltage drops (typical):

PV/Battery...................................... 0.4 volts

Battery/Load .................................. 0.3 volts

• Operating life.................................... 15 years

• Transient surge suppressors:

Pulse power rating ........................ 1500 watts

Response ...................................... < 5 nanosec

• 25% current overload capability ...... 5 minutes

• Reverse current leakage.................... < 10 µA

ENVIRONMENTAL

• Operating temperature .................... –40 to +85°C

• Max ambient temperature ................ +60°C

• Storage temperature ........................ –55 to +100°C

• Humidity............................................ 100%

MECHANICAL

• Dimensions: (inches) .... 6.0 x 2.2 x 1.3 (W•H•D)

(mm) ........ 152 x 56 x 33 (W•H•D)

• Weight

(oz)............ 8

(kg) .......... 0.23

• Wire terminals:

Wires per terminal...... 1 or 2 wires

Max size per wire........ #10 AWG

5.2 mm2

Screw material ............ Nickel plated brass

Terminal material........ Tin/Copper plated brass

• Encapsulation ................ Epoxy

• Case................................ 6063-T5 Aluminum

• Finish .............................. Electrolytic anodize

• Mounting orientation .... Any

CONTROL SETPOINTS

Sealed Flooded

• Low volt load disconnect ........ 11.5

11.5

• LVD reconnect .......................... 12.6

12.6

• Constant-voltage regulation .... 14.1

14.4

(24 V setpoints are twice 12 V values)

CONTROL PARAMETERS

• Charge algorithm .......... constant-voltage

series configuration

• PWM duty cycle.............. 0% to 100%

• Temp comp coefficient... –28 mV/°C (25°C ref) 12V

–56 mV/°C (25°C ref) 24V

• LVD delay ...................... 2 seconds

Specifications subject to change without notice.

E112204
For Use In Cl I, Div 2, Gp ABCD
Hazardous Locations
UL1604 CSA 22.2 No. 213-M1987