SPECIFICATION SUMMARY

SS-6

SS-10

SS-20

24 Volt

System Volts

(V)

12

12

12

24

Maximum PV Volts

(V)

25

25

25

44

Rated PV Input

(A)

6.5

10

20

n/a

Rated Load

(A)

6

10

20

n/a

Maximum array short

(A)

8.1

12.5

25

n/a

circuit current

Setpoints:

Sealed PWM

(V)

14.1

14.1

14.1

28.2

Flooded PWM

(V)

14.4

14.4

14.4

28.8

LVD

(V)

11.5

11.5

11.5

23.0

LVD Reconnect

(V)

12.6

12.6

12.6

25.2

Ambient Temp Range

(°C)

–40 to 60

–40 to 60

–40 to 60

–40 to 60

Temp Compensation

(mV/°C)

–28

–28

–28

–56

0.50

(13)

1.32

(34)

4 MOUNTING HOLES ø0.20 (5.0)

2.18

(55)

1.00

(25)

6.00 (152)

5.50 (140)

DIMENSIONS INCHES (MM)