C-1

APPENDIX C. PC208 ERROR MESSAGES

C.1 PC208E/GRAPHTERM ERROR

MESSAGES:

CANNOT HANG UP HAYES MODEM!
GraphTerm did not receive the proper response
to the +++ATZ Hayes MODEM command.

Cannot Enable Security
PC208E/GraphTerm was unable to enable
security on a 21X or CR7 datalogger. Security
may have been left unlocked.

Cannot Disable Security
PC208E/GraphTerm was unable to unlock
datalogger security.

RF MODEM does not respond!
GraphTerm did not receive the RF MODEM "!"
prompt as expected. Verify that the proper
COM port has been selected and that cabling is
correct. Baud rate must be either 300 or 1200.

Station name has an extension error:
When specifying a station file name, either omit
the extension or use .STN for the extension.

Datalogger Error E09 - Assign more Input
Storage Locations:
In the Monitor mode, a location(s) was
requested which has not been assigned as an
Input Location.

Sequential Communication Interruptions=
(number of times)
In the Monitor mode, requests to update the
screen have failed number of times. Telecommu-
nications path is very poor or has been interrupted.

Datalogger does not respond!
When attempting to exit telecommunications
the datalogger did not return an "*" as expected.

Datalogger Secure! Disable security first.
Disable security before attempting to program
or save the datalogger program.

Error - starting over.
The error detected while programming the
datalogger is such that GraphTerm must start
the process over to guarantee the datalogger is
programmed correctly.

Repeating last block.
While programming the datalogger, needed to
repeat a block of the program.

Download file is wrong type or too large!
While programming the datalogger, GraphTerm
received a message from the datalogger which
meant the program was either not recognized
as a program, or it was too large.

Exx, datalogger compile error detected.
After programming the datalogger, GraphTerm
received a message from the datalogger that
the program had a compile time error
designated by an "E" number. Refer to the
datalogger manual for a description of the
compiler error message.

Datalogger disconnected due to Exx.
GraphTerm quits, if possible, when a compile
time error message is received while
programming the dataloggers.

File (filename) not found.
The file GraphTerm needs to transmit does not
exist in the current directory.

Signature Error! TERM will repeat.
Repeat power-up PROM save.

Error in Datalogger Program!
An Exx error was detected when doing power-
up PROM save.

C.2 SPLIT ERROR MESSAGES:

Parameter following ";" must be an integer.
Check the Time Series functions where an
output interval has been assigned.

Invalid range specified inside [], or
expression buffer overflow.
On the Select parameter line you should check
that the range specified has two periods (..) or
that only digits are used a delimiters. Also,
check for a missing right or left bracket.

Input file does not exist or is not a data file,
or not enough files in system configuration.
Check the data file to see that it is valid. Also,
check your system configuration (config.sys) to
verify that it will open the number of files you are
working with.

Parameter file is too big.
You have exceeded the maximum parameter
file size of 4700 bytes.