SECTION 2. EDLOG

2-9

2.5.3.1 The Editor's Screen

FIGURE 2.5-1. Input Location Editor Screen

The Input Location Editor Screen (Figure 2.5-1)
provides the following information:

Addr

Lists the input location number (address).

Name

The input location labels are between the
brackets.

Flags

Automatically displays an R, W, and/or M, under
these conditions:

R -- indicates the input location has been read.

W -- indicates data are written to this location.

M -- indicates the input location has been

modified with the MANUALLY TOGGLE
command. See Section 2.5.3.2 for a
description of the MANUALLY TOGGLE
command.

# Reads

Automatically displays the number of times the
input location is read.

# Writes

Automatically displays the number of times that
data are written to this location.

Blocks

Contains the word 'START' when the input
location is the initial location for a group of reps.

Contains the word 'MEMBER' when the input
location is part of a group of reps but is not the
initial nor the last rep.

Contains the word 'END' when the input location
is the last rep.

2.5.3.2 Using the Commands

The commands listed at the bottom of the Input
Location Editor Screen (Figure 2.5-1) have the
following functions:

INSERT (F2) -- inserts an input location. This
automatically changes the input location
numbers for all of the labels that are after the
inserted location.

DELETE (F3) -- deletes the input location label,
flags, number of reads and writes, and block
information for a designated location number.
Whenever the datalogger program references a