5 *7 mode displaying final readings, 5 *7 mode dis- playing final readings – Campbell Scientific PST3/PST8 Pump and Slug Test System User Manual

Page 20

Advertising
background image

Recorded data can be verified from the keyboard/display in *7 mode.
Data retrieval should be done with a PC running PCPST.

07:XXXX

where XXXX is the next location in the ring memory
where data will be stored.

Commands Specific to *7 Mode:
#

Display Final Storage location number:enter location to
advance to, or C to display data

#A

Advance to same element in next array with the same
ID

#B

Back up to same element in previous array with the
same ID

Example:
Only one data point at a time can be viewed. The data will look some-
thing like this for the first 0.3 seconds of a Delta interval, 0.0 datum,
elapsed time test with 3 wells:

01:99

Indicates that the following is a header. This header
contains the startup information when a test is stopped.

02:1106

Start time (military time)

03:74.5

Starting depth of water

04:0003

Number of wells

05:0097

Location ID number (chosen by the user in *4 table)

06:0217

Day of year

07:12:29

Battery voltage at start of test

Then proceeding into the data

01:0001

Well number

02:.0075

Time in decimal minutes

03:.423

Water level

04:0002

Well number

05:00.875

Time

06:0.366

Water level

07:0003

Well number

ETC.