SECTION 5. TECHNICAL DETAILS - SOFTWARE

5.1 README FILE

This file contains the full text of the users
manual for PCPST menu software. It briefly
describes the contents of the Campbell
Scientific PCPST diskette and how to install the
software on a computer. This file may also be
viewed on the computer screen after installing
PCPST by entering "readme" at the DOS
prompt.

5.2 INSTALLATION

5.2.1 WORKING COPY

An example of a DOS command to make a
working copy of the diskette in drive A: follows:

1.

Make sure that the distribution diskette is
write protected. Have a blank formatted
diskette labeled "PCPST--working copy"
ready for step 2.

2.

Insert the distribution diskette in floppy drive
A: and enter:

diskcopy a: a

Then press "Enter".

3.

Follow the directions provided by DOS as it
guides you through the diskcopy procedure.
When this step is completed, you may use
the new working copy of PCPST.

5.3 INSTALLATION AND OPERATION

WITHOUT A HARD DISK

5.3.1 DOS PATH

Before beginning PST operations, you must
install PC208 Datalogger Support Software so
that PC208 program files are available to
PCPST. If PC208 was installed previously, you
may want to install PCPST into the same
directory as PC208. If you install them into
separate subdirectories, you should add the
subdirectory containing PC208 to your DOS

PATH. For example, if you installed PC208 in a
subdirectory named PC208 on drive C:, the
following line in your AUTOEXEC.BAT file
would make PC208 accessible to PCPST:

set path=c:\;c:\dos;c:\pc208

5.3.2 PC208 INSTALLATION

To install the PC208 Software, insert diskette 1
(marked 1 of 3) in a floppy disk drive. After
logging onto the disk drive, type "INSTALL".
The INSTALL program will prompt:

PC208 Datalogger Support

Software Install Program ver.

X.X

To abort the installation, type "Ctrl-C" or "Break"
at any time.

The Monochrome display mode should be
specified when installing for a computer which
uses a Monochrome Display Adapter (MDA).
The Black & White display mode is for
computers which have a Color Graphics
Adapter (CGA) with a monochrome monitor.
With other adapter/monitor combinations,
specify the default display mode.

Select a display mode (B = Black & White, M =
Monochrome, D = Default). Select the
appropriate option, and Install will prompt:

Enter name of drive containing

PC208 disk:

Enter the appropriate drive letter for your
computer (A: or B:). This is the drive that has
the PC208 diskette in it. Install will prompt:

Enter destination drive and path

name:

Enter the drive and path in which the PC208
software is to be installed. The installation
program for PCPST has already created a
subdirectory \PST. Next, Install will prompt: