TABLE 3. Function of NumRec, TFInterval, and TFUnits Parameters

NumRec/
Time Into
Interval
(d)
Entry



TFInterval
(e)
Entry



TFUnits
(f)
Entry




Function

0 0

N/A
(compiler
ignores)

When the SC115 is connected
to the datalogger, the
datalogger automatically
sends to the SC115 only the
data collected after the SC115
was last connected. The
datalogger will not send
additional data if the SC115
remains connected to the
datalogger.

0 -1

N/A
(compiler
ignores)

When the SC115 is connected
to the datalogger, the
datalogger automatically
sends to the SC115 all of the
data contained in the
datalogger’s memory. The
datalogger will not send
additional data if the SC115
remains connected to the
datalogger.

number of
data
records
(value > 0)

0 N/A

(compiler
ignores)

The datalogger sends the
specified number of data
records to the SC115 when
the data records become
available. For example, if the
NumRec parameter is set to 20
and TFInterval is set to 0, the
datalogger will write twenty
records to the SC115 when
twenty records become
available.

time into
interval
(value ≥ 0)

interval
(value > 0)

mSec, uSec,
Sec, Min, Hr,
or Day

The datalogger sends data to
the SC115 at the specified
interval. For example, when
the NumRec/Time Into
Interval
parameter is set to 0,
the TFInterval parameter is
set to 60 and the TFUnit
parameter is set to Min, the
datalogger will write data to
the SC115 every 60 minutes.

The following sections explain each TableFile() parameter in detail.