Campbell Scientific SDM-CAN Datalogger to CANbus Interface User Manual

Page 39

Advertising
background image

SDM-CAN Datalogger-to-CANbus Interface

;Send switch settings to SDM-CAN

7: SDM-CAN (P118)

1: 0

SDM

Address

2: 2

Time

Quanta

3: 5

Tseg1

4: 2

Tseg2

5: 1

ID

Bits

0..10

6: 0

ID

Bits

11..23

7: 0

ID

Bits

24..28

8: 32

Set

switches

9: 00

Start

Bit

No.

10: 00

No.

of

Bits

11: 00

No.

of

Values

12: 3

Loc [ Switches ]

13: 1.0

Mult

14: 0.0

Offset


;Set flag 1 low after sending switch settings

8: Do (P86)

1: 21

Set

Flag

1

Low


9: End (P95)


10: Batt Voltage (P10)

1: 4

Loc [ Battery ]


11: Internal Temperature (P17)

1: 5

Loc

[

Int_Temp

]


12: Thermocouple Temp (DIFF) (P14)

1: 6

Reps

2: 1

2.5

mV

Slow

Range

3: 1

DIFF

Channel

4: 1

Type

T

(Copper-Constantan)

5: 5

Ref Temp (Deg. C) Loc [ Int_Temp ]

6: 6

Loc [ TC_1 ]

7: 1.0

Mult

8: 0.0

Offset


;Transmit Data on to CAN network

13: SDM-CAN (P118)
1: 0

SDM

Address

2: 2

Time

Quanta

3: 5

Tseg1

4: 2

Tseg2

5: 1

ID

Bits

0..10

6: 0

ID

Bits

11..23

7: 0

ID

Bits

24..28

8: 20

Tx, unsigned int, LSB 1st

9: 1

Start

Bit

No.

10: 16

No.

of

Bits

11: 1

No.

of

Values

12: 6

Loc [ TC_1 ]

31