Campbell Scientific SDM-CAN Datalogger to CANbus Interface User Manual

Page 72

Advertising
background image

Appendix D. Examples of CAN Data Frames and Data Encoding and Decoding

16bit data frame with one 12bit unsigned integer value MSByte first

Rxed Bit order within bytes

87654321

87654321

Rxed Byte order

Byte 1

Byte 2

Values

A A

Bit order within values

12 9

8 1

Value byte order

MSNib

LSByte

Start bit (parameter 09:) RH ref

16 13

12 9 8 1

Start bit (parameter 09:) LH ref

1 4

5 8 9 16

Start bit (parameter 09:) Right Hand reference.
1: SDM-CAN (P118)
1: 0

SDM

Address

2: 1

Time-quanta

3: 5

Tseg1

4: 2

Tseg2

5: 1000

ID

Bits

0..10

6: 0000

ID

Bits

11..23

7: 00

ID

Bits

24..28

8: 1

Rx,

unsigned

int,

MSB

1st

9: 1

Start

Bit

No.

10: 12

No.

of

Bits

11: 1

No.

of

Values

12: 1

Loc [ value_A ]

13: 1.0

Mult

14: 0.0

Offset


Start bit (parameter 09:) Left Hand reference.
2: SDM-CAN (P118)
1: 00

SDM

Address

2: 1

Time-quanta

3: 5

Tseg1

4: 4

Tseg2

5: 1001

ID

Bits

0..10

6: 0000

ID

Bits

11..23

7: 00

ID

Bits

24..28

8: 1

Rx,

unsigned

int,

MSB

1st

9: 16

-- Start

Bit

No.

10: 12

No.

of

Bits

11: 1

No.

of

Values

12: 1

Loc [ value_A ]

13: 1.0

Mult

14: 0.0

Offset

D-10

Advertising