Campbell Scientific Solar1000 Station User Manual
Page 35

Met One 034B Windset
The set screw holes must be covered with the labels to
prevent corrosion and assure the warranty.
CAUTION
Mount the CM200-series crossarm to the tripod or tower. Orient the crossarm
North-South, with the 1” NU-RAIL or CM220 on the North end.
Remove the alignment screw at the base of the 034B (Figure
4-1). Insert the
034B into the aluminum bushing provided with the sensor. Align the hole in
the bushing with that in the 034B base and replace the screw. Insert the
034B/bushing into the NU-RAIL fitting or the CM220’s u-bolt (Figure
4-2).
Align the sensor so that the counter weight points to true south and tighten the
set screws on the NU-RAIL or U-bolts on the CM220. Remove the shoulder
screw to allow the vane to rotate.
Appendix A
of the original 034B manual contains detailed information on
determining true north using a compass and the magnetic declination for the site.
N
Set screw holes
must be covered
with labels
Shoulder
Screw
Alignment
Screw
Bushing
Crossarm
17953 NU-RAIL
FIGURE
4-1. 034B Mounted on a Crossarm Using a 17953 NU-RAIL Crossover Fitting