Wiring – Campbell Scientific Solar1000 Station User Manual
Page 36

Met One 034B Windset
CM220
CM200 Series Crossarm
FIGURE
4-2. CM200 Series Crossarm with
CM220 Right Angle Mounting Bracket
Attach the sensor cable to the six pin male connector on the 034B. Make sure
the connector is properly keyed. Finger tighten the knurled ring. Route the
sensor cable along the underside of the crossarm to the tripod/tower, and to the
instrument enclosure. Secure the cable to the crossarm and tripod/tower using
cable ties.
4.4. Wiring
Connections to Campbell Scientific dataloggers are given in Table
4.4-1. When
Short Cut for Windows software is used to create the datalogger program, the
sensor should be wired to the channels shown on the wiring diagram created
by Short Cut.
Color
Wire Label
CR800
CR5000
CR3000
CR1000
CR510
CR500
CR10(X)
21X
CR7
CR23X
CR200(X)
Red
WS
Signal
Pulse Pulse Pulse P_LL
Black
WS Signal Ref
G
Green
WD Signal
SE Analog
SE Analog
SE Analog
SE Analog
Blue
WD Volt Excite
Excitation
(VX)
Excitation Excitation Excitation
(VX)
White
WD Signal Ref
AG
Clear Shield
G
32
Table 4.4-1 Connections to Campbell Scientific Dataloggers