Nl115, Ethernet interface and compactflash® module, Specifi cations – Campbell Scientific Solar1000 Station User Manual
Page 62
NL115
Ethernet Interface and CompactFlash® Module
Specifi cations
Compliance:
CE Compliant
Power
Requirements:
12 V supplied through the data-
logger’s
peripheral
port
Current Drain:
20 mA (CR1000 w/NL115 com-
municating
over
Ethernet)
43 mA (CR1000 w/NL115 com-
municating
over
Ethernet
and
accessing
CF-card)
Temperature
Range
Standard:
-25° to +50°C
Extended:
-40° to +85°C
EMI and ESD Protection:
Meets requirements for a
class
A
device
under
European
Standards
Application
of
Council
Directive(s):
89/336/EEC as amended by
89/336/EEC
and
93/68/EEC
Standards to which
Conformity
is
Declared:
EN55022-1; 1995 and
EN50082-1:
1992
Typical Access Speed
2
:
200 to 400 kbits s
-1
Memory
Confi guration:
User selectable; ring (default) or
fi ll-and-stop
Datalogger
Operating
System (OS):
The CR1000’s OS must be OS 9 or
later. Both the CR1000 and
CR3000 need OS 25 or later
to read cards with more than
2 GB of storage.
Software
Requirements
LoggerNet:
Version 3.2 or later
PC400:
Version 1.3 or later
DevConfi g:
Version 1.5 or later
Cable
Requirements:
Ethernet cable must be shielded
if the length is greater than 9 ft
CF Card Requirements:
Industrial grade
Dimensions:
10.2 x 8.9 x 6.4 cm
(4.0 x 3.5 x 2.5 in.)
Weight:
154 g (5.4 oz)
NL115 connects
directly to the
peripheral port
CR1000
2
Typical Access Speed varies between dataloggers.