Nl115, Ethernet interface and compactflash® module, Specifi cations – Campbell Scientific Solar1000 Station User Manual

Page 62

Advertising
background image

NL115

Ethernet Interface and CompactFlash® Module

Specifi cations

Compliance:

CE Compliant

Power

Requirements:

12 V supplied through the data-

logger’s

peripheral

port

Current Drain:

20 mA (CR1000 w/NL115 com-

municating

over

Ethernet)

43 mA (CR1000 w/NL115 com-

municating

over

Ethernet

and

accessing

CF-card)

Temperature

Range

Standard:

-25° to +50°C

Extended:

-40° to +85°C

EMI and ESD Protection:

Meets requirements for a

class

A

device

under

European

Standards

Application

of

Council

Directive(s):

89/336/EEC as amended by

89/336/EEC

and

93/68/EEC

Standards to which

Conformity

is

Declared:

EN55022-1; 1995 and

EN50082-1:

1992

Typical Access Speed

2

:

200 to 400 kbits s

-1

Memory

Confi guration:

User selectable; ring (default) or

fi ll-and-stop

Datalogger

Operating

System (OS):

The CR1000’s OS must be OS 9 or

later. Both the CR1000 and

CR3000 need OS 25 or later

to read cards with more than

2 GB of storage.

Software

Requirements

LoggerNet:

Version 3.2 or later

PC400:

Version 1.3 or later

DevConfi g:

Version 1.5 or later

Cable

Requirements:

Ethernet cable must be shielded

if the length is greater than 9 ft

CF Card Requirements:

Industrial grade

Dimensions:

10.2 x 8.9 x 6.4 cm

(4.0 x 3.5 x 2.5 in.)

Weight:

154 g (5.4 oz)

NL115 connects
directly to the
peripheral port

CR1000

2

Typical Access Speed varies between dataloggers.