12 vdc regulator and power supply, Specifi cations – Campbell Scientific Solar1000 Station User Manual
Page 57

CH100 and PS100
12 Vdc Regulator and Power Supply
Specifi cations*
Output
Voltage:
12 Vdc
Nominal
Capacity:
7 Amp hours
Input
Voltage
(CHG
terminals):
15 to 28 VDC or 18 VAC RMS
Battery
Connections
Charging
Output
Voltage:
Temperature compensated
fl oat charge for battery
Temperature
Compensation
Range:
-40º to +60ºC
Max. Charging Current:
1.2 A (allows one SP20 or SP10
to
be
used)
Power Out (+12 terminals)
Voltage:
Unregulated 12 V from battery
Temperature
Current
Limited
with
3
A
Thermal
Fuse:
> 3 A @ < 20°C; 3 A @ 20°C;
2.1A @ 50°C; 1.8 A @ 60°C
CH100
Weight:
5.5 oz. (158 g)
CH100
Dimensions
Height:
4.0” (10.2 cm)
Width:
2.76” (7.0 cm)
Depth:
1.5” (3.9 cm)
PS100
Weight:
6.9 lb (3.1 kg)
PS100 Dimensions (including mounts and connectors)
Height:
4.1” (10.5 cm)
Width:
7.6” (19.0 cm)
Depth:
2.8” (7.0cm)
The PS100 is used with our CR800, CR850, or CR1000 datalog-
gers. It includes a rechargeable battery and a regulator.
The CH100 controls the current fl owing to the battery and pre-
vents the battery current from fl owing to the charging source.