Appendix A. Modifying the Non-Volatile Memory

A-3

4: If (X<=>F) (P89)
1: 3

X Loc [ Raw_Dist ]

2: 3

>=

3: -1000

F

4: 30

Then

Do


5: Z=X (P31)

1: 3

X Loc [ Raw_Dist ]

2: 8

Z Loc [ DEPTH ]


6: Z=X (P31)

1: 4

X Loc [ Raw_Qual ]

2: 9

Z Loc [ QUALITY ]


7: Z=F x 10^n (P30)

1: 0.0

F

2: 00

n, Exponent of 10

3: 5

Z Loc [ FAILCOUNT ]


8: Else (P94)

; If the measurement was not valid, increment the failure counter.

9: Z=Z+1 (P32)

1: 5

Z Loc [ FAILCOUNT ]


; If the failure counter is equal to or larger than a pre-determined number (in this case ; 3),
; allow the -99999 to appear in the data to indicate that there is a problem with the
; measurement. The pre-determined number will depend on the scan rate, and
; should
; indicate the maximum expected -99999 readings prior to a valid measurement being
; returned. The number should be 3 for scan rate greater than three seconds, and
; larger for faster execution rates.

10: If (X<=>F) (P89)

1: 5

X Loc [ FAILCOUNT ]

2:

3

>=

3:

3

F

4:

30

Then

Do


11: Z=X (P31)

1: 3

X Loc [ Raw_Dist ]

2: 8

Z Loc [ DEPTH ]


12: Z=X (P31)

1: 4

X Loc [ Raw_Qual ]

2: 9

Z Loc [ QUALITY ]


13: Z=F x 10^n (P30)

1: 0.0

F

2: 00

n, Exponent of 10

3: 5

Z Loc [ FAILCOUNT ]