6 p127, command 5: clear tx312 error registers, 7 p127, command 6: return tx312 to on-line mode, 6 edlog programming examples – Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual

Page 38

Advertising
background image

TX312 Transmitter

TABLE 5.2-7. Error Codes

Error Codes:
Hex Decimal

0x00 00

No

error

0x01 01

Illegal

command

0x02 02

Command

rejected

0x03

03

Illegal checksum or too much data

0x04

04

Time out or too little data

0x05 05

Illegal

parameter

0x06

06

Transmit buffer overflow

0x10

16

Message abort due to PLL

0x11

17

Message abort due to GPS

0x12

18

Message abort due to power supply – internal 16 volt – RF

0x13 19

Software

fault

0x14 20

Failsafe

fault

0x15

21

GPS time sync fault

0x16

22

SWR fault – transmission antenna connection

0x19

25

Internal RF power supply failure

See Section 5.1.2.4 for more information.

5.2.5.6 P127, Command 5: Clear TX312 Error Registers

Clear error registers of TX312. Requires one input location.

TABLE 5.2-8. P127 Command 5: Clear Error Registers

In Loc

Contents

1 Result

Code

Result code of 0 indicates success. Command 5 is used to erase all errors from
the error registers of the TX312.

5.2.5.7 P127, Command 6: Return TX312 to on-line mode.

Command 6 is used to return the TX312 to online mode. Typically used after
a forced random transmission. The TX312 has an off-line time-out of one
hour.

TABLE 5.2-9. P127 Command 6: Force On-line Mode

In Loc Contents

1 Result

code

Result code of 0 indicates success.

5.2.6 Edlog Programming Examples

Edlog instruction 126 is used to copy data from the datalogger final storage
area to the TX312 data buffer.

32