Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual

Page 53

Advertising
background image

Appendix D. RAWS-7 Data Format

D-5

; Measure Fuel Moisture
; Wiring:
; Power enable: C8
; Signal: SE 12
4: Period Average (SE) (P27)
1: 1

Reps

2: 4

200 kHz Max Freq @ 2 V Peak to Peak, Period Output

3: 12

SE

Channel

4: 10

No.

of

Cycles

5: 5

Timeout (units = 0.01 seconds)

6: 28

Loc [ FuelM ]

7: .001

Mult

8: 0

Offset


5: Do (P86)
1: 58

Set Port 8 Low


; Measure temperature and RH (HMP45C-L)
6: Excitation with Delay (P22)
1: 1

Ex

Channel

2: 0

Delay W/Ex (units = 0.01 sec)

3: 15

Delay After Ex (units = 0.01 sec)

4: 0

mV

Excitation


7: Volt (SE) (P1)
1: 1

Reps

2: 25

2500 mV 60 Hz Rejection Range

3: 2

SE

Channel

4: 3

Loc [ AirTemp ]

5: .1

Mult

6: -40

Offset


8: Volt (SE) (P1)
1: 1

Reps

2: 25

2500 mV 60 Hz Rejection Range

3: 1

SE

Channel

4: 4

Loc [ RH ]

5: .1

Mult

6: 0

Offset


; Measure wind speed (03001-L)
9: Pulse (P3)
1: 1

Reps

2: 1

Pulse

Channel

1

3: 21

Low Level AC, Output Hz

4: 5

Loc [ Wspd ]

5: 1.677

Mult

;

MPH

6: 0.4

Offset

Advertising