Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual

Page 64

Advertising
background image

Appendix D. RAWS-7 Data Format

D-16

3: Z=X*F (P37)
1: 35

X Loc [ Batt_load ]

2: .1

F

3: 35

Z Loc [ Batt_load ]


4: Z=X*F (P37)
1: 36

X Loc [ GPSAccTm ]

2: 10

F

3: 36

Z Loc [ GPSAccTm ]


5: End (P95)

; Set datalogger clock to GPS time once a day
6: If time is (P92)
1: 150

Minutes (Seconds --) into a

2: 1440

Interval (same units as above)

3: 30

Then

Do


7: HDR GOES Status (P127)
1: 0

Read

Time

2: 44

Result Code Loc [ time_rc ]


8: If (X<=>F) (P89)

1: 44

X Loc [ time_rc ]

2: 4

<

3: 1

F

4: 30

Then

Do

9: If (X<=>F) (P89)

1: 45

X Loc [ GPS_hour ]

2: 3

>=

3: 0

F

4: 30

Then

Do

10: If (X<=>F) (P89)

1: 45

X Loc [ GPS_hour ]

2: 4

<

3: 24.1

F

4: 30

Then

Do

11: Set Real Time Clock (P114)

1: 0

Set Hr,Min,Sec from locations

2: 45

Loc [ GPS_hour ]

12: End (P95)

13: End (P95)

14: End (P95)

15: End (P95)

16: If time is (P92)

1: 0

Minutes (Seconds --) into a

2: 180

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)