4 p127, command 3: transmit random message, 5 p127, command 4: read tx320 error registers, P127, command 3: transmit random message – Campbell Scientific TX320 Transmitter User Manual

Page 42: P127, command 4: read tx320 error registers, 9. p127 command 3: initiate random transmission, 10. p127 command 4: read tx320 error registers

Advertising
background image

TX320 Transmitter

7.6.5.4 P127, Command 3: Transmit Random Message

Overwrite random buffer with 1 2 3 4 (ASCII)

During GPS acquisition, the LED lights green.

During transmission, the LED lights red.

TABLE 7-9. P127 Command 3: Initiate Random Transmission

In Loc

Contents

1 Result

Code


Random message channel and repeat interval must be enabled in the TX320
configuration. If random messages have not been enabled, command 3 will
fail. If the GPS acquisition fails, the random transmission will fail. Command
3 will pull the TX320 offline. After the random transmission attempt, the
TX320 must be put back on line with command 6. When command 6 is used,
all data in the TX320 is erased. Random transmission may require up to five
minutes (GPS timeout) for setup and transmission. If command 6 is executed
before transmission, random transmission will be canceled.

During GPS acquisition, the LED will light solid green. During transmission,
the LED will light solid red. Command 3 will return 1 value, the command
result code. Zero indicates a successful execution of command 3, but does not
indicate the random transmission has happened or was successful.

7.6.5.5 P127, Command 4: Read TX320 Error Registers

Read error registers of TX320. Requires 10 input locations.

TABLE 7-10. P127 Command 4: Read TX320 Error Registers

In Loc

Contents

1 Result

Code

2 Number

of

Errors

3

Command that Caused the Error

4 Error

Code

5

Command that Caused the Error

6 Error

Code

7

Command that Caused the Error

8 Error

Code

9

Command that Caused the Error

10 Error

Code


See Section 8.3, Error Codes, for error code table and more information.

32

Advertising