F.3.5 Set Self-Timed transmission First Transmission Time

Syntax:

FTT=hh:mm:ss

Access level: USER
TX320 State: Disabled

Set the time for the first timed transmission of the day. Valid range is 00:00:00
to 23:59:59. The First Transmission Time is also referred to as the Offset, and
is between 00:00:00 and the Self-Timed Transmission Interval.

F.3.6 Set Self-Timed Transmission Transmit Window Length

Syntax:

TWL=xxx

Access level: USER
TX320 State: Disabled

Set the length of the timed transmit window. Length is specified in seconds.
Valid range is 5 to 240 seconds.

F.3.7 Enable or Disable Self-Timed Transmission Message

Centering

Syntax:

CMSG=Y/N

Access level: USER
TX320 State: Disabled

Center the timed transmission in the assigned window if Y otherwise transmit
at beginning of assigned window.

F.3.8 Enable or Disable Self-Timed Buffer Empty Message

Syntax:

EBM=Y/N

Access level: USER
TX320 State: Disabled

If EBM is Y, send “BUFFER EMPTY” message if the buffer is empty at time
of transmission. If EBM is N, do not transmit if the buffer is empty.

THIS IS NOT FULLY IMPLEMENTED! CURRENTLY IF BUFFER IS
EMPTY AT TRANSMIT TIME A MESSAGE IS WRITTEN TO THE
AUDIT LOG IF EBM=Y