Appendix F. Extended ASCII Command Set

Loading data into the random transmission buffer, triggers the random
reporting sequence. Once triggered, the random reporting mechanism will
send the data loaded in the buffer for the number of transmissions as specified
by the random repeat count. The buffer will be cleared automatically when the
number of transmissions specified have occurred.

If the command is received within 1 minute or during a random transmission,
the data will not be included in the current transmission but will be buffered for
the next one.

If there is more data loaded into the buffer than can be transmitted at the
assigned bit rate the message will be truncated.

F.4.6 Read Length of the Message in the Random

Transmission Buffer

Syntax:

RML

Access level: USER
TX320 State: Enabled/Disabled

Returns the number of bytes stored in the random transmission buffer.

F.4.7 Read the Maximum Random Message Length

Syntax:

MRML

Access level: USER
TX320 State: Enabled

Returns the maximum number of bytes that can be transmitted at the current
random transmission bit rate.

F.4.8 Clear Random Transmission Buffer

Syntax:

CRB

Access level: USER
TX320 State: Enabled/Disabled

Clear the random transmission buffer.

F.5 Status and Other Commands

The following commands are used by the host to determine the status of the
transmitter for display and diagnostics purposes. These commands can be
entered with transmissions enabled or disabled.