F.5.8 read reflected power, F.5.9 read power supply, F.5.10 read tcxo temperature – Campbell Scientific TX320 Transmitter User Manual

Page 78: F.5.11 read measured frequency, F.5.8 read, F.5.9 read

Advertising
background image

Appendix F. Extended ASCII Command Set

F-16

F.5.8 Read Reflected Power

Syntax:

RRFL

Access level: USER
TX320 State: Enabled/Disabled

Returns the reflected power in dBm. This value is updated at the bit rate when
transmitting and every 30 seconds when not transmitting.

F.5.9 Read Power Supply

Syntax:

RPS

Access level: USER
TX320 State: Enabled/Disabled

Returns the power supply voltage in volts. This value is updated at the bit rate
when transmitting and every 30 seconds when not transmitting.

F.5.10 Read TCXO Temperature

Syntax:

RTEMP

Access level: USER
TX320 State: Enabled/Disabled

Returns the TCXO temperature (PCB temperature) in degrees C. This value is
updated at the bit rate when transmitting and every 30 seconds when not
transmitting.

F.5.11 Read Measured Frequency

Syntax:

RMF

Access level: TECHNICIAN
TX320 State: Enabled/Disabled

This command returns the last measured OCXO and TCXO frequencies in the
following format:

F-OCXO: 10000005.9000
F-TCXO: 43199.9166

Units are Hz.

Advertising