2 confirming and/or changing region id – ArtDio IPC 1000 Series User Manual

Page 13

Advertising
background image

ARTDio IPP 1000 Series

12

4-2 CONFIRMING and/or CHANGING REGION ID

If you are installing your IPP unit in the default region, you may skip this procedure. The

default region is printed on a label on the shipping box (see example below).
If you are installing the unit in any region other than that specified on the label, you will need to
re-configure the IPP unit to the correct Region ID.
See the appendix for 12-1 List of Region ID By Country

To use the console, use the following procedure:


IPP>enable
IPP #configure
Enter configuration commands, one per line. End with CNTL/Z
IPP (config)#regional_id 07
IPP (config)#exit
IPP #delete nvram
This command resets the system with factory defaults.
All system parameters will revert to their default factory settings. All static
and dynamic addresses will be removed.
Reset system with factory defaults, [Y]es or [N]o? Yes

4-2.1 HOW TO OBTAIN AN IP ADDRESS

The IPP unit requires an IP address for operation. Before installation you need to determine

how to obtain an IP address from your local ISP. Static IP, DHCP, or PPPoE can all be used. The
following table helps you determine what information you will need. If your ISP offers static IP,
you may need to obtain an IP from MIS staff to prevent an IP conflict. Otherwise, DHCP (as
provided by most broadband cable), and PPPoE (provided by most ADSL broadband providers) will
work correctly.

Advertising