IP Environment

Required Information

Public IP address

IP address

Subnet mask

Default Gateway

It is recommended that you obtain an IP address from
MIS staff in order to prevent an IP conflict.

Static IP

Private IP address

IP address
Subnet mask
Default Gateway

It is recommended that you obtain an IP address from
MIS staff in order to prevent an IP conflict.

Note:Your private IP requires an IP sharing device, and
this device must be configured to treat the IPP unit, and
the IP it is using as a ‘virtual server’.

Dynamic IP Address (DHCP)

DHCP Mode

PPPoE

Account Number
Password
This information is normally provided by your ISP . If
you don’t have this information, contact your ISP.


4-2.2 SETTING THE IP

The IP address can be set via the console, or the Web Management Page.

To use the console, use the following procedure:

IPP >enable
IPP #configure
Enter configuration commands, one per line. End with CNTL/Z
IPP (config)#ip state user
IPP (config)#ip address 210.62.149.250 255.255.255.128
System needs to restart
IPP (config)#ip default-gateway 210.62.149.254
IPP (config)#exit
IPP #restart
This command resets the system. System will restart operation code agent.
Reset system, [Y]es or [N]o? Yes