Alto-Shaam Combitherm 4.10ESi User Manual

Page 13

Advertising
background image

CT ExpRESS INSTALLATION MANUAL • 11 .

m o b i l e e q u i p m e n t r e s t r a i n t

i n s t a l l a t i o n

any appliance that is not furnished with a
power supply cord but includes a set of casters,
stand with casters, or a stacked configuration
must be installed with a tether. adequate means
must be provided to limit the movement of this
appliance without depending on or transmitting
stress to the electrical conduit. The following
requirements apply:

1.

casters must be a maximum height of 6" (152mm).

2.

Two of the casters must be the locking type.

3.

such appliances must be installed with the use
of a flexible connector secured to the
building structure.

4.

each of the stacked appliances must be
installed with the use of a flexible connector
secured to the building structure. a single wall
anchor may be used.

a mounting connector for a restraining device is
located on the top right back panel of the appliance
chassis or on an oven stand, approximately
18" (457mm) from the floor. a flexible connector is
not supplied by nor is it available from the factory.

w a r n i n g

risk of electric shock.

Appliance must be secured

to building structure.

Mounting connector for
restraining device

Advertising