To start a local management session, perform the following procedure:
1. Connect one end of the null modem management cable included
with the switch to the RS232 Terminal Port on a master of the stack.
The master switch has a Stack ID of 1. (The STACK ID LEDs on the front
of the switches will tell you which is the master switch of the stack.)
Figure 1 Connecting a Terminal or PC to the RS232 Terminal Port
2. Connect the other end of the cable to an RS232 port on a terminal or
a PC with a terminal emulation program.
3. Configure the terminal or terminal emulation program as follows:
❑ Emulation mode: VT100
❑ Baud rate: 9600
❑ Data bits: 8
❑ Parity: None
❑ Stop bits: 1
❑ Flow control: None
❑ Key mode: Terminal keys
DE
RS232