Vertical contact toaster, Operation, A.j. antunes & co – A.J. Antunes & Co VCT-1000 9210717 User Manual

Page 8: Operating instructions, Safety features

Advertising
background image

Vertical contact toaster

8

P/N 1010884 Rev. D 04/12

A.J. Antunes & Co.

1

2

4

5 1 = 1/2"(12.7mm)

2 = 5/8"(15.9mm)

3 = 11/16"(17.5mm)

6 = 7/8"(22.2mm)

THICKNESS

THICKNESS

1

2

3

4

6

6

5

4 = 3/4"(19.1mm)
5 = 13/16"(20.6mm)

3

Operating instructions

OperatiOn

1

2

3

4

5

1 = 1/2"(12.7mm)
2 = 5/8"(15.9mm)

4 = 3/4"(19.1mm)
5 =13/16"(20.6mm)
6 = 7/8"(22.2mm)

THICKNESS

THICKNESS

1

2

3

4

5

6

6

3 =11/16"(17.5mm)

figure 3. bun thickness compression Knobs

figure 2. toaster controls

bun thickness

adjustment controls

bun Landing

area

Power switch

Hi-Limit Reset

temperature control

(see figure 3)

Reset

button

Protective

cap

impOrtant

Verify that the Release sheet is installed completely

over the Platen (figure 1) before proceeding. failure

to use Release sheet may cause permanent damage

to the Platen surface that is not covered by warranty.

1. Set the Bun Thickness compression Knobs

(figure 3) to the desired settings.

2. turn the unit on.

3. turn the temperature control to 10. allow the unit

to warm up for 30 minutes before proceeding.

4. slide buns across the rotating butter Wheel with

the cut face down and drop buns into toaster

(figure 2). cut sides of heel and crown must face

each other.

nOte: after initial run of 4–6 buns, adjust controls

according to the desired finished product.
5. toasted product will drop into the bun Landing

area (figure 2).

6. test at least 4 buns before putting toaster into

service. turn temperature control to lower setting

for lighter toasting or to higher setting for darker

toasting.

7 turn the unit off when finished toasting and follow

the daily cleaning procedures.

safety features

Hi-limit reset buttOn

a Hi-Limit control turns off electrical power to the heat-

er if the Platen overheats. to reset this control, allow

10–15 minutes for the unit to cool down. then remove

the Protective cap, fully press the Reset button located

at the rear of the unit, and replace the Protective cap

(figure 2).

if the unit requires continuous resetting, contact your

authorized service agency.

cOnVeyOr interlOcK safety switcH

a conveyor interlock safety switch is located on top of

the unit under the Heat shield (figure 1). the conveyor

belt chains will not rotate unless the Heat shield is

seated properly in place and activating the conveyor

interlock safety switch.