Problem

Possible Cause

Corrective Action

No heat and conveyor

belts do not move.

Toaster is installed incorrectly.

Perform the installation and operating proce-

dures found in the Installation and Operation

sections of this manual.

Inoperable power cord or Power

Switch.

Check receptacle for correct voltage (see the

Specifications section of this manual).

If necessary, contact your maintenance person

or Authorized Service Agency for service.

Hi-Limit Control is tripped.

Reset the Hi-Limit Control.

Wiring problem.

Contact your maintenance person or Authorized

Service Agency for service.

No heat but Conveyor

Belt Chains rotate.

Wiring problem.

Contact your maintenance person or Authorized

Service Agency for service.

Inoperative Platen.
Inoperable Thermostat

Platen is hot but

Conveyor Belt Chains do

not rotate.

Heat Shield not installed.

Install Heat Shield.

Conveyor Safety Interlock Switch not

activated by the Heat Shield.

Re-install the Heat Shield correctly so that the

Heat Shield applies appropriate pressure on the

Conveyor Safety Interlock Switch.

Spring Tensioner Assembly is

damaged or missing.

Replace Spring Tensioner if damaged or

missing.

Conveyor Belt Chain links too loose. Adjust Conveyor Belt Chain length as described

in the Maintenance section of this manual.

Inoperable Drive Motor.

Contact your maintenance person or Authorized

Service Agency.

Loose Drive Motor Sprocket

Setscrew.
Drive Motor Chain has fallen off

sprocket(s).
Inoperable Safety Interlock Switch.

Conveyor Belt Chains

hesitate to rotate and/or

skip on sprockets.

Conveyor Belt Chains installed

incorrectly.

Install Conveyor Belt Chains as described in the

Maintenance section of this manual. Be sure that

the ends of the hooks are facing down.

Conveyor Belt Chains too loose.

Adjust Conveyor Belt Chain length as described

in the Maintenance section of this manual.

Spring Tensioner Assembly is

damaged or missing.

Replace Spring Tensioner Assembly if damaged

or missing.

Advertising