Installation (continued), A.j. antunes & co – A.J. Antunes & Co UFL-440 9700472 User Manual

Page 10

Advertising
background image

UFL-420/440 water FiLtration system

10

P/N 1010864 Rev. C 03/12

A.J. Antunes & Co.

caUtIOn

Ingesting the protective solution may cause irrita-

tion of the gastrointestinal tract, colic, diarrhea, or

other similar symptoms

properly for the plumbing line. This valve will allow for

easier servicing and future cartridge change out.

DraIn lIne plUmbInG

The drain line is used to flush away the particle buildup

when cleaning the filter. The drain line must be able

to support the flow rate when the system flushes. The

flow rate from the flush depends on the inlet water pres-

sure, inlet pipe size, and system selected. It is recom-

mended that the drain line be as large as, or larger

than, the inlet plumbing line. The drain line should be

as short as possible, sloping downward without kinks

or loops. Be sure that the drain used is not blocked or

restricted.
The filter system must be protected from possible back

contamination by the installation of an air gap between

the drain connection of the system and the drain

(Figure 4). This gap in the line, with no physical contact

between the system and sewer, prevents contamination

of the system in the event of a backed-up sewer.
nOte: make sure that the end of the drain line is

positioned and secured at least 2 inches above

the drain so that the water flow is directed into the

drain, without splashing.

Install tHe cartrIDGe

Install the cartridge into the housing by following the

instructions on page 15 in the Changing the Cartridges

area of the Maintenance section in this manual. Make

sure that all o-rings are lubricated with a food-grade

silicone lubricate before assembling

flUsHInG tHe sYstem

To ensure that the highest quality water is produced

from the system, the plumbing leading from the filter

system must be flushed clear of all debris after the

system is hooked up. After making the connection

to the outlet of the filter system, open a faucet or tap

closest to the filter system, then slowly open the inlet

water valve. Allow the pipe to flush until all debris is

removed.

The unit also must be flushed to remove air and the

shipping/storage solution. For maximum quality, the

permeate water produced during the flushing procedure

must be discarded. Direct this permeate water to drain.

InstallatIOn (continued)

1. Plug the power cord into the appropriate electrical

outlet. The unit will power on and the LED display

will display the following for about two seconds

each:

8.8

FD followed by its time settings in seconds

Fi and its time setting in minutes or hours.

The

F and F sequence repeats for about 20 sec-

onds after which the switches to Flush Mode (FL)

before returning to the Flush Interval Mode (F).

The time setting for F1 will be displayed and the

decimal point will flash in one second intervals.

2. open the tap or faucet closest downstream to the

filter system.

3. Slowly open the inlet water valve and allow water

to enter the system.

4. Press and hold the Program button. After 6-7

seconds, the drain valve will open and F1 will

appear on the display.

5. Continue holding the Program button down for at

least 60 seconds to keep the drain valve open.

This flushes air out of the center of the hollow

fibers. The drain will remain open as long as the

Program button is pressed. Check to make sure

that the drain water is directed into the drain with-

out splashing.

6. Release the Program button. This closes the

drain valve. Water should continue to flow

through the system and out of the open tap.

Allow water to flow out of the tap for at least 15

minutes at maximum flow rate.

7. Close the tap and let the system stand without

water flow for 15 minutes to allow any trapped air

to come out of the hollow fibers. Check for leaks

at all fittings.

8. After 15 minutes without water flow, open the

tap for 5 minutes to allow any trapped air to be

flushed out. Close the tap.

9. once again, press and hold the Program button

for at least 60 seconds to flush out any remaining

air from the system.

10. Release the Program button. Flushing is

complete.