maIntenance

The filtration system is designed to require very little

maintenance. To ensure that the water is of the highest

quality, occasionally some service is required.

checking the timer program

During normal operation, the system displays the time

setting for the Flush Interval Mode (FI) and the deci-

mal will flash in one second intervals. This is the time

between flushing, not a time of day setting.
over time, it is possible that the time that the system

flushes occurs at a time of high water use. If this cre-

ates a problem, the timer can be reset by unplugging

the power cord, waiting for 5 seconds, and plugging the

power cord in again. The timer then begins timing from

the point power is restored to the system. Follow the

procedures within the operation section of this manual

to check and set the timer settings.

changing the cartridges

While the filtration system is designed for long life,

eventually the cartridges will need to be replaced.

nOte: Do nOt operate the system without the flow

regulator assembly or the unit will be damaged,

physical injury may occur, and the warranty will be

voided.
1. open the faucet or tap closest downstream to the

filtration system.

2. Close the inlet water valve and allow the system

to depressurize.

3. Place a bucket under the “T” or cross fitting at the

inlet connection to the system. open the valve or

unscrew the cap to drain the system.

4. Press and hold the Start button to help drain the

system.

5. Close the inlet drain valve or reattach the cap on

the “T” fitting when the water flow stops.

6. Unplug the system.

7.

make sure there is enough room below the

housing to remove the cartridge.

8. Remove the snap ring on the end of the housing.

Grab the raised lug with your fingers or a pair of

pliers and pull towards the center of the end cap

and away. The ring should lift out of its groove.

9. The end cap, end cap o-ring, and cartridge

should easily drop down out of the housing. If

not, pull gently on the end cap to remove.

10. Inspect the cartridge o-rings and end cap o-ring

for nicks or cuts. Replace as needed.

11. Lubricate all o-rings with a food-grade silicone

lubricant. Apply a light coating of lubricant to the

inside center tube at both ends of the new car-

tridge..

12. Place the end cap o-ring on the end cap and

insert the end cap into the end of the new car-

tridge. Position the new cartridge and end cap

below the housing and gently insert into the hous-

ing. Press the end cap into position until the end

cap is fully seated and the snap ring groove is

visible.

13. Install the snap ring by guiding the non-lugged

end into the groove first, pushing outward and

working around the ring until it snaps into place.

nOte: make sure that the snap ring is fully seated

before turning the water on.

14. Follow the Flushing and Starting the System and

Sanitizing the System and Lines procedures in the

Installation section of this manual to complete the

cartridge change.

If the cartridge does not easily come out of the housing,

the opposite end cap can also be removed for assis-

tance during Step 8. Remember to inspect and reinstall

the o-rings at each end in the proper order.

system sanitization

over time and use, the plumbing downstream from the

system may require sanitization. It is recommended

that the system and downstream plumbing be sani-

tized at least once a year. When necessary, follow

the Sanitizing the System and Lines procedure in the

Installation section of this manual.