UFL-420/440 water FiLtration system

5

P/N 1010864 Rev. C 03/12

A.J. Antunes & Co.

specIfIcatIOns

electrical ratings

Dimensions

caUtIOn

all electrical connections must be in accordance

with local electrical codes and any other

applicable codes.

Ufl-440

a

width

b

Depth

c

Height

Operating

weight

(w/water)

(lbs)

min. clearance

for cartridge

change above

or below unit

(inches)

11.5 in

6 in

47 in

42 lbs.

38 in

figure 1. Dimensions

electrical cord & plug configurations

letter

code*

Description

configuration

C

H

Commercial Cord

Harmonized Cord

(H)C**

CEE 7/7, 16 Amp.,

250 VAC (Assembly

only).

(C)F***

5-15P, 15 Amp., 120

VAC., Non – Locking

(Assembly only).

WHT BLK

GRN

* Used in model Designation

** indicates that the Plug comes with a Harmonized Cord

** indicates that the Plug comes with a Commercial Cord

Ufl-420

a

width

b

Depth

c

Height

Operating

weight

(w/water)

(lbs)

min. clearance

for cartridge

change above

or below unit

(inches)

11.5 in

6 in

28 in

28 lbs.

19 in

replacement cartrIDGe

UFL-420

L-420 (P/N 7000411)

UFL-440

L-440 (P/N 7000412)

C

B

A

model &

mfg. no.

Voltage

watts

amps

Hertz

UFL-420

9700460

120

10

.085

50/60

UFL-420

9700462

230

10

.04

50/60

UFL-440

9700470

120

10

.085

50/60

UFL-440

9700472

230

10

.04

50/60