Operation (continued), A.j. antunes & co – A.J. Antunes & Co UFL-440 9700472 User Manual

Page 14

Advertising
background image

UFL-420/440 water FiLtration system

14

P/N 1010864 Rev. C 03/12

A.J. Antunes & Co.

OperatIOn (continued)

PROGRAM

PROGRAM

3-

programming timer while Unit is in flush

Interval (fi) mode

tO set fi - flUsH InterVal mODe

nOte: after power-up and cycling - fi time setting

displays a flashing decimal point.

1. Press and hold the Program button for four

seconds. Release the button and the LED will

display Fd followed by its setting.

2. When Fi (Figure 10) is displayed, press and

release the Program button to view current set-

ting.

3. To make a change, press and hold the Program

button to scroll through settings - release the but-

ton at desired setting (Figure 11).

4. The unit automatically returns to the Flush

Interval Mode if the Program button is not

pressed within 10 seconds.

nOte: fi times are displayed in ten minute inter-

vals, after fifty minutes they are displayed in hours

(table b).

tO set fD - flUsH DUratIOn mODe

1. Press and hold the Program button for four

seconds. Release the button, the LED displays

Fd.

2. When Fd is displayed (Figure 12), press and

release button to view current setting .

3. To make a change, press and hold down start

button to scroll through settings - release button

at desired setting (Figure 13).

4. After ten seconds, if start button is not pressed

unit automatically returns to Flush Interval Mode.

nOte: fd times are displayed in 5 second intervals

up to 60 seconds (table b).

PROGRAM

3-

PROGRAM

15

figure 12. leD Display for flush Duration

figure 13. time Display for fd mode (15 seconds)

table b. leD Display settings

figure 11. time display for fi mode (30 minutes)

figure 10. fi - leD Display for flush Interval mode

1-

10 minutes

5

5 seconds

5-

50 Minutes

10

10 seconds

01 1 Hour

15

15 Seconds

12

12 Hours

30

30 Seconds

24 24 hours

60

60 Seconds

Fi - Flush Interval Mode

Fd - Flush Duration Mode

manual flushing

nOte: manual flushing only works when unit is in

flush Interval mode (fi).

While the unit is in Flush Interval Mode (decimal point

flashing), hold the Program button down for 6-7 sec-

onds until the LED displays FL (Figure 14). Continue

holding the button down to keep the drain open. Drain

will remain open for as long as Program button is

depressed. (FL will flash on LED.) Releasing the but-

ton closes the drain and puts the unit back into startup

mode. After ten seconds, if the Program button is not

pressed the unit automatically returns to the Flush Interval

Mode (Fi).

Advertising