Installation instructions, A) installing or replacing the lamp, Procedure – elektraLite MY 575w User Manual

Page 4

Advertising
background image

-

3 - MY575 WASH

Installation Instructions.

a) Installing or replacing the lamp

Only install the lamp when MY575w is unplugged from 120 volts.
The lamps must be replaced when it has reached the end of its lamp life or if it is damaged or deformed.

Before replacing the lamp let the lamp cool down. During operation, the lamp can
reach very high temperature.
During the installation of the lamp do not touch the glass bulbs with bare hands. Always use a cloth to handle
the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate temperatures higher than MY575w operating
temperature.

For the installation, you need one MSR 575/2 lamp :


Procedure:

1) Unscrew the 3 screws (A, B, C) on the bottom of the housing, holding the plate under which the lamp is

located. Carefully remove the metal plate.

2) Carefully insert the lamp into the socket. Please remember the lamp is polarized. There is only one way to

insert the lamp. Gently slide the lamp and its lamp holder back into place.

3) On the access plate there are 3 screws marked 1, 2 and 3. They are used to adjust the lamp. You can

adjust the 3 screws to fine-tune the position of the lamp and get the maximum light output.

2

3

1

2

1

3

Please remember the lamp is not hot-restrike. You must wait approximately 10
minutes before you can restrike the lamp.

Do not ever operate MY575w with the cover open. The lamp is a discharge lamp. All discharge lamps,
irregardless of the manufacturer or type, are very volatile and can explode. Great caution must be exercised
when working with these lamps otherwise serious injury can happen.