3 controller keypad wiring, Figure 3 – HID EntryProx Installation Guide User Manual
Page 12

Part No. 4045-905, Rev C.2 EntryProx
™
User Guide
Figure 3 Pulling Wires through the Backplate
4.3
CONTROLLER KEYPAD WIRING
In a standard installation, the antenna housing remains installed in
the controller keypad, and the complete unit is installed outside of
the secured area. This is appropriate for interior doors or “low-
risk” exterior installations.
For compliance with the UL294 Standard, additional installation
requirements must be met – see INSTALLATION COMPLIANCE
FOR UL 294, page 20.
To wire the EntryProx unit for a standard installation, refer to
Figure 4 and follow these instructions.
1. Touch a grounded object
BEFORE
touching the main
circuit board to guard against possible static
discharges.
2. Remove the main circuit board by pushing outward on
the two spring tabs in the direction shown in Figure 4.
3. Lift the main circuit board.
4. Make the wiring connections for the door locking
devices, the power supply, and the alarm inputs and
outputs. Refer to WIRING, page 23 for appropriate
wiring diagrams.
Page 12 of 58
February 7, 2007
© 2007 HID Global Corporation. All rights reserved.