5 wiring, Figure 11 – HID EntryProx Installation Guide User Manual
Page 23

EntryProx™ User Guide
Part No. 4045-905, Rev C.2
5 WIRING
Figure 11 illustrates the location and description of the four pin connectors on
the main circuit board and its use. Connector P5 is not used.
Blue – Not Used
Brown – Wiegand LED Control
White – Wiegand Data 1
Green – Wiegand Data 0
Red – Power +12 VDC
Green – Aux Relay NO
Black – Ground
Gray – Aux Relay NC
Blue – Main Relay COM
Blue – Aux Relay COM
Green – Main Relay NO
Brown – Rex Loop
Gray – Main Relay NC
Orange – Door Loop
White – Loop Common*
*Note: Rex Loop
requires NO switch;
Door Loop requires
NC switch. Connect
commons from both
loops to Loop
Common input P2, Pin
6, White.
Red – LED (Red +)
Black – LED (Green +)
Antenna +
Antenna -
Figure 11 Pin Locator Diagram
February 7, 2007
Page 23 of 58
© 2007 HID Global Corporation. All rights reserved.