HID EntryProx Installation Guide User Manual
Page 51

EntryProx™ User Guide
Part No. 4045-905, Rev C.2
IF YOU WANT
Ref
PRESS
DETAILS
TO
9 Download
programmed user
list (starting at a
certain user)
25 # 0 # start
user # **
Hold optional Palm PDA IR
receiver near the EntryProx
IR LED.
10 Change
Wiegand
& Miscellaneous
parameters
32 # parameter
# value # **
Parameter/Value
0, Wiegand pulse width,
default=8, 160µs, (1=20µs),
range= 1- 255
1, Wiegand interpulse
spacing, default=32, 640µs,
(1=20µs), range=1-255
2, facility code/0-225
(default = 1) (26-bit cards
only) verify!
3, Process card timer 2 – 240
in ¼ second increments,
defaults to 4 – 1 second††
4, Invalid PIN lockout
threshold 1 –50 attempts
(defaults to 5)
5, Invalid PIN lockout
duration 1 – 255 in 5 second
increments (defaults to 60 -
5 minutes)
11
Set system time
41 # hhmm # 0
# **
hhmm = hour/minute,
24-hr format
12
Set system date
42 # mmddyy #
dow # **
mmddyy =
month, day, year;
dow = day of week,
1 = Sunday
13
Set door number
43 # nnnn # 0 #
**
nnnn = door number (for
downloaded reports)
February 7, 2007
Page 51 of 58
© 2007 HID Global Corporation. All rights reserved.