Technical specifications – Karcher HD 10-16-4 Cage Ex User Manual

Page 23

Advertising
background image

– 10

Technical specifications

Type

HD 10/16-4
Cage Ex

Power connection
Voltage

V

400

Current type

--

3~

Frequency

Hz

50

Connection output

kW

5,5

Mains fuse (slow-blow)

A

16

Maximum allowed net impedance

Ohm

(0,086+j0,054)

Water connection
Max. feed pressure

MPa (bar)

1 (10)

Max. feed temperature

°C

50

Min. feed volume

l/min (l/h)

16,7 (1000)

Inlet hose length (min.)

m

7,5

Inlet hose diameter (min.)

Inch

3/4

Performance data
Working pressure

MPa (bar)

16 (160)

Max. excess operating pressure (safety valve)

MPa (bar)

22,0 (220)

Flow rate

l/min (l/h)

16,7 (1000)

Nozzle size

--

60

Recoil force of trigger gun

N

35

Values determined as per EN 60355-2-79
Noise emission
Sound pressure level L

pA

dB(A)

71

Uncertainty K

pA

dB(A)

2

Sound power level L

WA

+ Uncertainty K

WA

dB(A)

87

Hand-arm vibration value
Hand spray gun

m/s

2

<2,5

Spray lance

m/s

2

<2,5

Uncertainty K

m/s

2

1

Fuel
Oil quantity - pump

l

2

Oil type - pipe

--

Hypoid SAE 90
(6.288-016.0)

Dimensions and weights
Length

mm

980

Width

mm

720

Height

mm

1100

Typical operating weight

kg

114

Miscellaneous
Ambient temperature

°C

+5...+40

Ignition protection class

Ex II G c T3

23

EN

Advertising
This manual is related to the following products: