Function – Karcher SB-WASH 50-10 User Manual

Page 31

Advertising
background image

-

8

1 Water connection (by customer)
2 Pipe disconnector (optional)
3 salt tank (optional)
4 base exchanger (optional)
5 Control head (optional)
6 condensing electro motor
7 swimming valve
8 Swimming container anti freeze
9 swimming valve
10 proportioning device water softener flu-

id (RM 110, optional)

11 Swimming container fresh water
12 filter anti freeze pump
13 Centrifugal pump
14 Strainer
15 Back up valve
16 Proportioning valve cleaning agent
17 Reactor *)
18 High pressure pump
19 Manometer *)
20 Overflow valve *)
21 Dosing pump
22 Cleaning agent filter
23 Cleaning agent container

24 Fuil container
25 Fuil pipeline
26 Burner fan
27 Fuil pump inclusive bypass valve
28 Flow indicator
29 Fuil valve
30 Flame indicator
31 Burner inclusive flow-type heater
32 Temerature limiter
33 Attemperator
34 Hand blowing gun
*) in the cylinder head of the high pressure
pump.

During cleaning, the water flows through

Water connection

base exchanger (optional)

condensing electro motor

High pressure pump

Continuous heater

to hand-spray gun.

If there is danger of frost, the water is flows
through the following cycle:

Swimmer tank with anti-freeze

Centrifugal pump

High pressure hose

Trigger gun

Swimmer tank with anti-freeze

Has the softening capacity of the base ex-
changer reached 80%, than the night
folling, a regeneration process will be pre-
formed.

If the burner does not firem, or the flame goes
out during the operation, then the flame indica-
tor does turn off the flow of the fuel.

If the lever of the hand blowing gun is let
loose during the operation, then the cycle
valve will open, and the high pressure
pump will stay in operation. When opening
the blowing gun gain, the high pressure jet
does function.

Does avoid, that the burner is turned on, if
there is a lack of water.

If the power supply is interrupted because
of a short circuit or overload.

IThe motor power supply is interrupted be-
cause of overheating.

Adjusts the warm ater temperature accord-
ing to the setting.

The burner turns off at the temperature of
75 °C .

Turns on the anti freeze cycle by danger of
frost (unter 3 °C) .

Function

Flow pattern

Functional description

Monitoring and safety devices

Hardness sensor in the base exchang-
er (optional)

Flame indicator

Overflow valve *)

Flow indicator

Circuit breaker

Winding head thermostat

Attemperator

Temperature limitor

Anti freeze thermostat

31

EN

Advertising