37 en, Interruption with a display of the operating panel, Interruption shown on the display – Karcher SB-WASH 50-10 User Manual

Page 37: Faults without display

Advertising
background image

-

14

Interruption with a display of the operating panel

Interruption

Possible cause

Repair

by whom

Contol light flame indica-
tor, temperature limiter
lights up

burn material container is empty

Pour in the fuel

Operator

The burner filter is clogged up

Clean the burner material filter.

Operator

Photocell flame indicator is not put in properly or
is missing

Check, if the photocell is placed properly.

Operator

Interruption concerning the burn material pump
or the burn material magnet valve

Check the parts, if needed replace.

Maintenance

Contol light flame indica-
tor, temperature limiter is
blinking

The temperature limiter has triggered off

Open the blowing gun, until the equipment has cooled
down. Turn the equipment at the operating panel on and
off, in oder to unlock the temerature limiter. If there is the
case of repetition, call the Service.

Operator

Interruption shown on the display

Display

Cause

Repair

By whom

E001

Set off the motor protection switch high
pressure pump

Turn back the motor protection switch, if it does occure again, call
the Service.

Operator

E002

Fuse - F1 has tiggered off, circulating
pump, heat fan

E003

interruption of the burner

Turn off the equipment, wait, turn on the equipment.

Operator

E004

Tank permeat is empty ( only with the
option Top-Maintenance)

Refer to the operation manual of the RO equipment (optional).

Operator

E005

Cleaning agent, burning material empty
(optional)

Check the container, if needed refill, start the equipment.

Operator

E100

Interruption control circuit

Turn off the equipment, wait, turn on the equipment.

Operator

Faults without display

Fault

Possible cause

Remedy

By whom

Plant is not running

Mains fuse have got triggered

Check mains fuses and mains voltage

Operator

No pressure build-up in
the plant or pump is
knocking

Amount of water supply is too low.

Check water supply level (refer to technical data).

Operator

Heating coil has heavy calcium deposits

base exchanger (optional) or water softener with RM 110 (op-
tional) does not work. Rectify cause, decalcify the plant.

Operator, Cus-
tomer Service

Pipe is blocked

Check all pipes to see that there are no blockages

Operator

System is sucking air

Check system for leaks, the detergent suction hoses must lie
in the detergent, refill detergent container.

Operator

Check the pump hose for cracks and wear; replace if required. Operator, Cus-

tomer Service

Program 4 (optional, by
ABS half load program 5)
no function

Wrong adjustment in the function menue

Set the "Osmosis" function in the function menu to "On".

Operator, Cus-
tomer Service

No reduced pressure
when using program 2
(only with ABS half load)

Set the "Half-load" function in the function menu to "On".

Operator, Cus-
tomer Service

Pump leaky (more than 3
drops of water per minute)

Defective pump part

Replace defective part.

Customer Serv-
ice

Detergent is not taken in

Filter or hose is blocked

Clean the parts.

Operator

Magnet valve or check valve defect

Replace valve.

Customer Serv-
ice

Pump hose of the dosing pump damaged. Check the pump hose for cracks and wear; replace if required. Operator, Cus-

tomer Service

high pressure pump does
draw air

Detergent container is empty

Refill detergent.

Operator

Burner does not ignite or
the flame glows off during
operation

The hot water was not adjusted for this
washing program.
No ignition

Check the adjusting the control circuit board

Operator

Check ignition.

Customer Serv-
ice

Check ignition electrodes.

Customer Serv-
ice

Too low water tempera-
ture for hot water opera-
tions

Temperature has been set too low.

Set the thermostat to a higher level.

Operator

Heating coil has heavy calcium deposits

base exchanger (optional) or water softener with RM 110 (op-
tional) does not work. Rectify cause, decalcify the plant.

Operator, Cus-
tomer Service

Nozzle in spray pipe is rinsed out.

Define the quantity to be transported by the pump. Replace
nozzle if the specifications given in the technical data are ex-
ceeded with a large margin.

Operator

Heating coil sooted

Remove the soot from the heating coil.

Customer Serv-
ice

37

EN

Advertising