Maintenance and care – Karcher HDC advanced User Manual

Page 23

Advertising
background image

English

23

ƽ

Danger

Risk of injury! The main switch is to be switched off while carrying out any repairs or maintenance jobs.

Maintenance and care

Maintenance schedule

Time

Activity

Assembly affected

Performance

of whom

daily

Check hand-
spray gun

Hand spraygun

Check whether the hand-spray gun closes tightly
without any leaks. Check the protection mecha-
nism against accidental switching. Replace de-
fective hand-spray guns.

Operator

Check high pres-
sure hoses

Outlets, hoses towards working
machine

Check hoses to see if there are damages. Re-
place defect hoses immediately. Danger of acci-
dent!

Operator

weekly or after 40
operating hours

Check the unit
for leaks

Entire plant

Check pumps, overflow valve and pipe system
for leaks. Inform Customer Service if there is oil
below the pump or if there is a leakage of more
than 3 drops of water per minute. Keep the leak-
age borings clear.

Operator/
Customer
service

Check oil level

Oil level indicator on the pump If the oil is milky, it needs to be replaced.

Operator

Check oil level

Oil level indicator on the pump Check oil level of the pump. Refill oil if required

(Order no. 6.288-016)

Operator

monthly or after 200
operating hours

Check pump

High-pressure pump

Check the pump for leaks. If the leakage is more
than 3 drops per minute, call Customer Service.

Operator

Check water
scarcity fuse

Swimmer switch in the swim-
mer tank

Press the swimmer of the low water fuse down
for about 5 seconds and control the error indica-
tor on the control board. Remove deposits if nec-
essary.

Customer
Service

Test swimmer
valve

Swimmer tank

The water level must be 40 mm above the over-
flow. No water must exit while the swimmer valve
is closed. Adjustment - see service manual.

Customer
Service

Check over-
pump time.

Controls

Close consumer loads (e.g. hand spray guns).
The pump must switch off after the afterrun peri-
od.

Operator

Test automatic
start

Pressure sensor

The pump stands still as there is no water trans-
fer. Open the hand spray gun. If the pressure in
the high-pressure cycle falls below the switch-
point, the pump must switch on.

Operator

Tighten hose
clips

All hose clips

Tighten the hose clips using a torque wrench.
Tightening torque up to a diameter of 28 mm =
2Nm, from 29 mm = 6 Nm.

Operator

half-yearly or after
1000 operating
hours

Oil change

High-pressure pump

Drain off oil. Fill in 1 l of fresh oil (order no. 6.288-
016.0). Check the oil level at the oil level indica-
tor.

Operator

Check the appli-
ance for calcium
deposits

entire water system

Improper functioning of valves or pumps can be
an indication of calcium deposits. If necessary
decalcify.

Operator
trained in de-
calcification

Tighten clamps Control board

Tighten all clamps for components in the main
circuit.

Electrician

annual

Safety check

Entire plant

Safety check according to the guidelines for fluid
spraying equipment.

Technical
expert

Depending on ambi-
ent conditions

Check the filter
mats of the ven-
tilator

Control board

Check the filter mats of the ventilator for contam-
ination and clean if necessary. Replace with new
filter mats after cleaning them 10 times.

Customer
Service

Advertising