Actiontec electronic Plug n' Play Voice/Fax Modem V.90 ISA User Manual

Page 61

Advertising
background image

61

S0

Auto Answer Ring Number

Range:

0

255

Default:

0

Units:

rings

This register determines the number of rings the modem will count before automati-
cally answering a call. Enter 0 (zero) if you do not want the modem to automatically
answer at all. When disabled, the modem can only answer with an ATA command.

S1

Ring Counter

Range:

0

255

Default:

0

Units:

rings

This register, Ring Counter, is read only. The value of S1 is incremented with each
ring. If no rings occur over a six second interval, this register is cleared.

S2

AT Escape Character (user defined)

Range:

0

255

Default:

43

Units:

ASCII

This register determines the ASCII valued used for an escape sequence. The default is
the + character. The escape sequence allows the modem to exit data mode and enter
command mode when on-line. Values greater than 127 disable the escape sequence.

S3

Command Line Termination Character (user defined)

Range:

0

127, ASCII decimal

Default:

13 (carriage return)

Units:

ASCII

This register determines the ASCII values as the carriage return character. This char-
acter is used to end command lines and result codes.

S4

Response Formatting Character (user defined)

Range:

0

127, ASCII decimal

Default:

10 (line feed)

Units:

ASCII

This register determines the ASCII value used as the line feed character. The modem
uses a line feed character in command mode when it responds to the computer.