Confirming/saving the measurement results – Sony HT-SS360 User Manual

Page 24

Advertising
background image

24

US

4

Press

to start the

measurement.

Measurement starts in 5 seconds.
While the time is counting down, stand
away from the measurement area to avoid
measurement error.
The measurement process will take
approximately 30 seconds to complete.

The table below shows the display when
measurement starts.

Note

If “CHK MIC” appears, you cannot perform the
Auto Calibration. Connect the calibration mic, then
restart the Auto Calibration.

Tips

• When Auto Calibration starts:

– Stand some distance from the speakers and the

listening position to avoid measurement failure.
This is because test signals are output from the
speakers during measurement.

– Avoid making noise to get a more accurate

measurement.

• The Auto Calibration function will be canceled

when you do the following during the
measurement process:

– Press ?/1 or MUTING.
– Press input buttons on the remote or INPUT

SELECTOR on the receiver.

– Change the volume level.

1

Confirm the measurement
result.

When the measurement ends, a beep
sounds and the measurement result
appears on the display.

2

Press

V/v repeatedly to select

the item. Then, press

.

Note

After “SAVE” is displayed for 50 seconds, the
measurement result is saved automatically,
without the need to save the procedure.

3

Save the measurement result.

Select “SAVE” in step 2.
The measurement results are saved.

Measurement for

Display

Speaker existance

TONE

Speaker gain, distance,
frequency response

T.S.P.

Subwoofer gain and distance

WOOFER

Confirming/saving the
measurement results

Measurement
result

Display

Explanation

When the
measurement
process
completes
properly

SAVE

Proceed to step
2.

When the
measurement
process fails

ERROR

XXXX

See “When
error codes
appear” (page
25).

Item

Explanation

SAVE

Saves the measurement
results and exits the setting
process.

WRN CHK

Displays warning
concerning the
measurement results. See
“When you select “WRN
CHK”” (page 25).

DIST

Displays the measurement
result for speaker distance.

LEVEL

Displays the measurement
result for speaker level.

EXIT

Exits the setting process
without saving the
measurement results.