Port status – Axis Communications AXIS 233D User Manual

Page 38

Advertising
background image

38

AXIS 233D - Event Configuration

Please see the online help

for descriptions of each available option.

High level

Only very large objects
trigger motion detection

An object that appears in the region will
trigger the motion detection for a long
period

Ordinary colored objects on ordinary
backgrounds will trigger the motion
detection

Low level

Even very small objects
trigger motion detection

An object that appears in the region will
trigger motion detection for only a very
short period

Only very bright objects on a dark back-
ground will trigger motion detection

Default value

Low

Medium to High

Medium to High

Examples:

• Avoid triggering on small objects in the video image by setting the

object size level to high.

• To reduce the number of triggers if there is a lot of movement during a short period of time, select a high

history level.

• To only detect flashing light, low

sensitivity can be selected. In other cases, a high sensitivity level is

recommended.

Port Status

Under Event Configuration > Port Status there is a list that shows the status for the

connected inputs and outputs of the AXIS 233D for the benefit of the Operator who cannot

access the System Options section.

Example:

If the Normal state for a push button (e.g. doorbell) connected to an input is set to

Open circuit - as

long as the button is not pushed, the state is i

nactive. If the push button is pushed, the state of the input

changes to

active.

Object Size

History

Sensitivity