AXIS 233D - I/O terminal Connectors

I/O terminal connector blocks

Power/Audio
1

Power AC

18 - 30 VAC max 25VA power consumption.

2

Power
AC/DC+

18 - 30 VAC max 25VA power consumption.
-or-
22 - 40 VDC max 20W power consumption.

3

GND

Ground

4

Vout

12V/200mA
Vout can be used to power auxiliary equipment,
max 200mA.

5

GND

Ground

6

Line OUT

Mono audio output (line level), which can be connected
to an active speaker with built-in amplifier.

7

GND

Ground

8

Mic/Line IN

Input for a mono microphone or line level mono signal.

Output
1

Out1_1_relay

On the external device output terminals (e.g. Out1_1 and
Out1_2) there is no distinction between positive and neg-
ative. The terminals use a photocoupler and are electri-
cally isolated from the other internal circuitry.

The maximum load should not exceed 500mA and the
maximum voltage should be not more than 50V DC.
Note: Connecting AC to the Output will damage the unit.

2

Out1_2_relay

3

Out2_1_relay

4

Out2_2_relay

5

Out3_1_relay

6

Out3_2_relay

7

Out4_1_relay

8

Out4_2_relay

Input
1

In1_anode(+)

Electrically isolated from the chassis and connectors,
these inputs can be supplied from an external DC voltage
or pin 4 (Vout) of the Power/Audio Connector and GND.
(3.3 - 40VDC allowed on the inputs)
The terminals use a photocoupler and are electrically iso-
lated from the other internal circuitry.


Note: There is a distinction between anode and cathode
when making connections!

2

In1_cathode(-)

3

In2_anode(+)

4

In2_cathode(-)

5

In3_anode(+)

6

In3_cathode(-)

7

In4_anode(+)

8

In4_cathode(-)

Pin Function

Description