Sony ECM-TL3 User Manual

Electret condenser microphone, Ecm-tl3, English

Advertising
background image

Electret Condenser

Microphone

ECM-TL3

©2011 Sony Corporation

Printed in China

English

Electret Condenser

Microphone

WARNING

To reduce the risk of fire or electric

shock, do not expose this

apparatus to rain or moisture.

To reduce the risk of electrical

shock, do not open the cabinet.

Refer servicing to qualified

personnel only.

You are cautioned that any changes or

modifications not expressly approved

in this manual could void your

authority to operate this equipment.

Features

 Records both sides of the telephone

conversation clearly.

 Best to use with a mobile phone

and/or landline.

 The microphone is covered with

silicon rubber to reduce noise when

it hits the receiver.

How to use

(see fig. )

1

Connect the plug to the
microphone jack of a plug-in-
power system recording device.

2

Wear the earpiece () securely
in your ear.

3

Put the speaker of the
telephone or mobile (
) next
to the microphone (
).

Align the holes in the speaker with

the holes of the microphone.

How to change the

earbud (see fig. )

If you cannot hear low sounds, or the

earbud does not fit your ear, try

another size. Confirm the size of the

earbud by checking the colored part

( of the sectional view) inside.

When you change the earbud, install it

firmly on the microphone to prevent

the earbud from detaching and

remaining in your ear.

Earbud sizes (inside color)

Small

Large

SS

*

(Red)

S

(Orange)

M

(Green)

L

(Light blue)

* This size is optional and available at

purchase.

To detach an earbud

(see fig. )

Twist and pull the earbud off.

Tip

If the earbud slips and cannot be detached,

wrap it in a dry soft cloth.

To attach an earbud

(see fig. )

Push the parts inside of the earbud into

the microphone until the projecting

part of the microphone is fully covered.

Troubleshooting

No sound, unable to record
 The connected recorder is not a

plug-in-power supply system device.

 Connect the microphone to a

plug-in-power supply system

device.

 Check with the operating

instructions of the connected

device.

 The connected recorder is a

monaural device.

 Use a PC-236MS stereo-monaural

converter plug (sold separately).

 The microphone is connected to the

headphone jack.

 Connect the microphone to the

microphone jack.

No sound, noisy sound
 The plug does not fit properly.

 Wipe the plug with a soft cloth.

 Insert the plug all the way into the

microphone jack, and make sure it

is secure.

Specifications

Type:

Electret condenser

microphone

Plug:

Three-conductor L-shaped

gold-plated mini plug

(monaural)

Power supply:

Plug-in-power supply

system

Wearing system:

Inner ear system

Directivity:

Omni-directional

Front sensitivity (Open circuit

output voltage level):

–35.0 dB (1,000 Hz, 0 dB =

1 V/Pa)

Frequency response:

20 Hz - 20,000 Hz

Cord length:

Approx. 1.5 m (59 1/8 in)

Mass:

Approx. 8 g (0.28 oz) (Incl.

cord)

Operating temperature:

5 °C to 35 °C

(41 °F to 95 °F)

Supplied accessories:

Earbuds

(S × 1, M × 1, L × 1)

Optional accessory:

PC-236MS stereo-monaural

converter plug

If the microphone is

connected to a monaural

recorder, the microphone

may not be able to work to

its full capability, depending

on the recorder. In such a

case, use the PC-236MS

stereo-monaural converter

plug.

Recommended accessory:

EP-EX10A earbud

Design and specifications are subject

to change without notice.

Precautions

 This microphone is a precision

instrument. Never disassemble it.

 Do not expose the microphone to a

mechanical shock such as by

dropping or striking it.

 If the microphone is placed near

speakers/headphones, a high pitched

noise may be heard (howling effect).

This is caused by the microphone

catching sound from the speakers/

headphones repeatedly. In this case,

place the microphone as far as

possible from the speakers/

headphones.

 Do not leave the microphone in a

humid, dusty or hot place, or under

direct sunlight. This may cause a

malfunction.

 When using outdoors, never let the

microphone become wet with rain

or saltwater.

 When the microphone and the plug

become dirty, wipe them with a dry

cloth. Do not blow on the

microphone when dusting it. A dirty

plug will cause deterioration of

sound quality and intermitted

sound.

 Always hold the plug when

disconnecting. Pulling the cord may

cause it to snap.

 Clean the earbud by hand-washing

with a mild detergent solution.

Remove the earbud when you clean

it. After cleaning, dry the earpiece

well before use.

 The earbud may deteriorate due to

long-term storage or use.

Note on static electricity

In particularly dry air conditions, mild

tingling may be felt on your ears. This

is a result of static electricity

accumulated in the body, and not a

malfunction of the microphone.

The effect can be minimized by

wearing clothes made from natural

materials.

EP-EX10A is available (sold

separately) as optional replacement

earbuds.

EP-EX10A offers 4 types of the

earbuds: SS, S, M and L.

4-273-321-11(1)

  

MIC

(PLUG IN POWER)

1

2

3

Operating Instructions
Mode d’emploi
Manual de instrucciones

Advertising