Avocent Cyclades-PR4000 User Manual

Page 39

Advertising
background image

Cyclades-PR4000

39

Chapter 4 - Step-by-Step Instructions

STEP TWO
No more parameters are necessary for the Ethernet interface. The other interface to be configured is the SWAN
in slot 1. The SWAN physical media parameters are shown in Figure 4.8. Fill in the values for your application.
The SWAN configuration is described in more detail in chapter 6 of the Installation Guide.

Menu CONFIG=>INTERFACE=>SWAN=>PHYSICAL
Parameter

Example

Your Application

Mode

Asynchronous

Speed

115.2k

FIGURE 4.8 SWAN PHYSICAL MENU PARAMETERS

STEP THREE
The network protocol parameters, shown in Figure 4.9, are similar to those for the Ethernet interface. Fill in the
parameters for your network in the right-most column. For an example using NAT where the Primary IP Address
is not dynamically assigned, see the chapter dedicated to NAT in the Installation Manual.

Menu CONFIG=>INTERFACE=>SWAN=>NETWORK PROTOCOL=>IP
Parameter

Example

Your Application

Active or Inactive

Active enables IP communication (IPX
and Transparent Bridge are not used in
this example).

Interface
Unnumbered/
Numbered

Numbered

Primary IP Address

0.0.0.0 (This number will be assigned
by the Access Provider dynamically.)

Subnet Mask

255.0.0.0

FIGURE 4.9 SWAN NETWORK PROTOCOL (IP) MENU PARAMETERS

Advertising